====== Resetting Engines from the Browser ====== The routine to invoke to reset engines created by the OEngineServer over the web is called **O4W_MANAGEENGINES**. If this routine is invoked with the “LIST=1” parameter (which is the default setting), it will display a list of OEngines. The call can be made as follows: http://www.mywebsite.com/virtual_directory/oecgi3.exe/O4W_MANAGEENGINES To invoke ‘reset’ behaviors password parameters must be passed. A ‘soft’ reset can be invoked with the following call: http:www.mywebsite.com/virtual_directory/oecgi4.exe/O4W_MANAGEENGINES?PWD=&FORCE=1 If your O4W (or INET) basic+ routine needs to shut down its _//own//_ engine in the EngineServer, it can call the new **RTI_KILLCURRENTOENGINE** stored procedure. Simply pass in the engine server password (for example, CALL RTI_KILLCURRENTOENGINE(“REVSOFT”)) and the current OEngine will be discarded after processing rather than re-queued for further use.