====== Send_Info subroutine ====== ==== Description ==== The Send_Info subroutine sets the text for the system receiver. If no receiver has been set, the subroutine displays a line of text in the OpenInsight System Monitor. ==== Syntax ==== **Send_Info**(//text//) ==== Parameters ==== The Send_Info subroutine has the following parameter: ^Parameter^Description^ |//Text//|The text to display in the status line or System Monitor.| ==== See Also ==== [[statusline|STATUSLINE property]], [[setdebugger|SetDebugger("SPY")]] ==== Remarks ==== While the system receiver is often whichever control has been set to be the STATUSLINE for a form, it is the system receiver which currently has focus in which the message is displayed. This function is particularly useful for debugging programs; it can be used to display information in the System Monitor without interrupting processing (like the debugger and messages do). In conjunction with [[setdebugger|SetDebugger("SPY")]], you can suppress or display event information on the System Monitor. ==== Example ==== * example 1: clear status line (if there is a status line) Send_Info(" ") * example 2: display a debugging message in the System Monitor (if there is no status line) */ if assigned(x) then Send_Info("Value of x is ": quote(x)) end else Send_Info("Value of x is not assigned") end