Configuration of OpenInsight's Internal Web Server
By default the OEngineServer’s built in Web Server is configured to listen on port 18888. You can change this port by either the OpenInsight IDE from Settings, IDE, Console or via the OI Console.
The contents of the eserver.cfg file are as follows:
#Fri Feb 13 15:05:11 BOT 2015 UserName= Mode= Procedure_1=REVCMD_LISTENER WebServerConnection_default=EXAMPLES,EXAMPLES,,,,RUN_OECGI_REQUEST,,,, Password= //=Process to run for mode -1,0,2 at 'idle check' Statistics_Directory=stats Server= WebServerVirtualDirs=o4w;examples;console WebServerVirtualPaths=o4w;o4w;o4w Statistics_Output=localhost\:18090 Statistics_Input=18090 IdleTimeout=15 WebServerConnection_console=SYSPROG,OICONSOLE,SYSPROG,,,RUN_OECGI_REQUEST,,,, MaxConnections=0 StartupFlags=65 WebServerConnection_o4w=SYSPROG,OICONSOLE,SYSPROG,,,RUN_OECGI_REQUEST,,,, WebServerConnection_examples=EXAMPLES,EXAMPLESO4W,EXAMPLESO4W,,,RUN_OECGI_REQUEST,,,, IdleCheck=60 TimerProc= PortNumber=18088 MaxUpTime=0 ShutdownProc= MaxEngines=10 Application= WebServerCGIProcedure=oecgi4.exe;oecgi3.exe Procedure_=JD3_LISTENER //CommandPort=18887 EControlPassword=oq19usRJ5UuBvTNyudv/H/7soWoRIq0k Statistics_Days=14 ShutdownFlags=1 WebServerPortNumber=18888 //WebServerConnection_examples= MaxRunTime=0 Statistics_ID=MAIN